Pulsar DFM 6.1-B-1-A-1-A-1-A-1-A Flow Meter

Doppler Ultrasonic Flow meters for dirty liquids, with datalogger
Pulsar Doppler Flow Meter DFM 6.1-B-1-A-1-A-1-A-1-A

Gaining flow measurement inside a pipe can sometimes be tricky. The DFM 6.1 Doppler Flow Meter works as a non-contacting, clamp-on flow meter to offer effective clamp-on pipe flow measurement from outside the pipe. Its Doppler technology makes it perfect for use as a water flow meter, specifically for difficult liquids, or liquids with suspended solids (i.e. Dirty Water) such as wastewater, slurries, sludge, chemicals, viscous liquids, and abrasives. The non-invasive Doppler ultrasonic flow meter fits a pipe 12.5 mm (0.5 in) inside diameter or larger, and clamps to the outside of the pipe, gaining flow measurement readings without interrupting the process.

Output: 4-20mA and 2 x Relay
Datalogger: 26M points
Cable Length: 7.6m
Power: 9-32VDC
Protection: IP66
Temp: -20° to 60°C
Sensor: SE4-A Clamp-on 12.5mm to 4.5m ID pipes